Termica Neo vs Thermal Simulation
What is the difference between old Thermal Simulation 2.x and new Termica Neo?
Thermal Simulation | Termica Neo | |
---|---|---|
Kinetics Methods | ||
Model-free methods | - | + |
Model-based methods | + | + |
Number of kinetic models | limited | unlimited |
Geometry | ||
Slab infinite | + | + |
Cylinder infinite | + | + |
Sphere | + | + |
Cylinder finite | - | + |
Container | ||
Using containers | - | + |
Adiabatic simulation | + | + |
Surrounding | ||
Different surrounding materials | - | + |
Any user-defined temperature program | only multi-step | + |
Material Library | ||
Material Library for reactants | - | + |
Material Library for containers | - | + |
Material Library for surroundings | - | + |
Simulation results | ||
Temperature | + | + |
Degree of conversion | + | + |
Conversion rate | + | + |
Concentrations for individual reactants | - | + |
Glass transition temperature (for reactions with diffusion control) | - | + |
Optimization | ||
SADT (self-accelerated decomposition temperature) | + | + |
Semenov Analysis | + | next versions |
Frank-Kamenetsky Analysis | + | next versions |
Visualization | ||
2D as temperaure-dependent curves for different coordinates | + | + |
2D as coordinate-dependent curves for different time points | - | + |
3D surface as the function of time and one selected coordinate | + | + |
3D heatmap as the function of time and one selected coordinate | + | + |
3D surface as the function of two coordinated for selected cross-section | - | + |
3D heatmap as the function of two coordinated for selected cross-section | - | + |
Results selected time point (+video) | + | + |
Results for selected coordinate | - | + |
Export | ||
ASCII Export | + | + |
Copy Graphic to Clipboard | + | + |
Export of section simulation (3D / Heatmap) to AVI video file | - | + |
Visual Settings | ||
Visual Themes for User Interface | - | + |
2D Chart: show/hide Legend | + | + |
2D Chart: show/hide curves by clicking on Legend | - | + |
2D Chart: show/hide Zoom bars | - | + |
2D Chart: show/hide Grid | - | + |
2D Chart: select Legend Font | + | + |
2D Chart: select Axis Font | - | + |
2D Chart: select Axis Thickness | - | + |
3D Chart: rotate 3D Surface | + | + |
3D Chart: show/hide Color Surface | - | + |
3D Chart: show/hide Contour Lines | - | + |
3D Chart: show/hide Wireframe | - | + |
3D Chart: select Gradient/Levels color Palette | - | + |
3D Chart: select Ortogonal/Perspective Projection Mode | - | + |
3D Chart: select Lighting and Opacity effects | - | + |
Heatmap Chart: show/hide Color Surface | - | + |
Heatmap Chart: show/hide Contour Lines | - | + |
Heatmap Chart: show/hide Lines Values | - | + |
Heatmap Chart: show/hide Grid Lines | - | + |
3D Chart: show/hide Datapoints for Polar Plot | - | + |